6 марта 2015 г.

HP DL360g7, RHEL 6 добавление дисков

- Вставляем диски в свободные слоты.


- С помощью ултилиты hpacucli (hpssacli) собираем новый массив из новых дисков.


=> ctrl all show detail
Smart Array P410i in Slot 0 (Embedded)
   Bus Interface: PCI
   Slot: 0
   Serial Number: 5901418017F2B3A9
   Cache Serial Number: POCAQ0CRHQY6IS
   RAID 6 (ADG) Status: Disabled
   Controller Status: OK
   Hardware Revision: C
   Firmware Version: 5.14
   Rebuild Priority: Medium
   Expand Priority: Medium
   Surface Scan Delay: 15 secs
   Surface Scan Mode: Idle
   Queue Depth: Automatic
   Monitor and Performance Delay: 60  min
   Elevator Sort: Enabled
   Degraded Performance Optimization: Disabled
   Inconsistency Repair Policy: Disabled
   Wait for Cache Room: Disabled
   Surface Analysis Inconsistency Notification: Disabled
   Post Prompt Timeout: 0 secs
   Cache Board Present: True
   Cache Status: OK
   Cache Ratio: 25% Read / 75% Write
   Drive Write Cache: Disabled
   Total Cache Size: 1024 MB
   Total Cache Memory Available: 912 MB
   No-Battery Write Cache: Disabled
   Cache Backup Power Source: Capacitors
   Battery/Capacitor Count: 1
   Battery/Capacitor Status: OK
   SATA NCQ Supported: True


Smart Array P410i in Slot 0 (Embedded)
   array A
      logicaldrive 1 (279.4 GB, RAID 1, OK)

=> ctrl serialnumber=5901418017F2B3A9 physicaldrive all show
Smart Array P410i in Slot 0 (Embedded)
   array A
      physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 300 GB, OK)
      physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 300 GB, OK)
      physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 300 GB, OK, spare)

   unassigned
      physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SAS, 300 GB, OK)
      physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SAS, 300 GB, OK)
      physicaldrive 2I:1:7 (port 2I:box 1:bay 7, SAS, 300 GB, OK)
      physicaldrive 2I:1:8 (port 2I:box 1:bay 8, SAS, 300 GB, OK)



=> ctrl serialnumber=5901418017F2B3A9 create type=ld drives=2I:1:5,2I:1:6,2I:1:7,2I:1:8 raid=1+0
=> ctrl serialnumber=5901418017F2B3A9 logicaldrive all show
Smart Array P410i in Slot 0 (Embedded)
   array A
      logicaldrive 1 (279.4 GB, RAID 1, OK)
   array B
      logicaldrive 2 (558.7 GB, RAID 1+0, OK)


В данном случае получили второй массив - RAID10.

-Если необходимо, нарезаем разделы через fdisk, создаем файловые системы или изменяем существующие разделы LVM. 

Комментариев нет: